Emergency Telephone Faltcom ECII ® Flex COP DUO
Zoom photo
202250

Emergency Telephone Faltcom ECII ® Flex DUO COP

The Telia ECII ® Flex DUO COP emergency telephone is an alarm system designed for elevators intended for passenger transport.

When a trapped passenger presses the alarm button, Telia ECII ® Flex DUO COP automatically sends an alarm to a predefined telephone number, preferably a 24-hour service center, at which the elevator is identified.

Two-way voice communication is then established and the passenger can communicate with the service center operator, who can undertake the appropriate action.

The Telia ECII ® Flex DUO COP system was designed with a focus on safety, simplicity and high reliability of operation. This system was developed in close cooperation with professional end users and industrial designers.

The audio quality of Telia ECII ® Flex DUO COP is exceptional even in difficult environments with background noise.

The FältCom ECII® Flex DUO COP phone is mounted with security screws and the front plate is made of stainless steel and vandal-proof.

The Telia ECII ® Flex DUO COP emergency phone complies with the new EN81:28 2018
and has new features for an even better operating reliability.

THIS MODEL 

  • Name: Telia ECII ® Flex DUO COP - emergency telephone only + numeric keypad
  • Dimensions: 100x90x19 mm
  • Weight: 200 g
Secure payments
Secure payments
Fast shipping
Fast shipping
Return policies
Return policies
Description

HOW DOES TELIA ECII FLEX DUO WORK?

The emergency phone is equipped with a built-in speaker, microphone, LED indicators, and input/outputs. It can be connected with a number of external devices, including intercom, loop amplifier, emergency power supply, Gateway etc. When adding a Gateway, a wireless telephone communication is created, enabling EC II Flex Duo to send alarms via the mobile network. When a passenger in an emergency presses the alarm button, the system automatically calls a pre-defined phone number. Bidirectional communication allows the person receiving the alarm to call the elevator and talk with the passenger. You can choose whether you wish for a pre-recorded voice message to be played inside the car, in order to calm passengers in an emergency.

Programming is easily done via a built-in keyboard, or remotely via standard telephone, Windows application Flex programmer, or the dedicated smartphone app. The elevator phone has a programmable input that can be used for e.g. an extra alarm button, technical alarm for the elevator controller, or filtration signals. It also has 2 programmable relay outputs that can be used for e.g. external pictograms, mechanical alarm button self test and/or elevator restart.

FEATURES

  • Certified with EN81:28 2018 standard.
  • Updated audio software for all pre-recordedmessages.
  • 2 programmable relays.
  • Pictogram output.
  • Button self-test.Unified software.

ECII Flex Duo is CE-marked and meets the requirements of European Standards EN81:28 2018, EN81:70, EN81:71 and EN81:80.

PORTS

  • Alarm 1: Input for alarm button (Normally Open / Normally Closed)
  • Alarm 2: Extra alarm input for additional alarm buttons, technical alarm, filtration, alarm acknowledgement, etc. Loop amp: Output for loop amplifier.
  • Phone: Connection to PSTN or gateway.
  • AUX: For speech units.
  • DC: Input for external power supply.
  • 2 Digital outputs: Isolated relays for external equipment e.g. pictogram, mechanical self test, elevator restart.

TECHNICAL SPECIFICATION

  • Enclosure: 1.5 mm stainless steel (ECII Flex Duo), 1.0 mm AluZinc (ECII Flex Duo Cop), 1.5 mm stainless steel (ECII Flex Duo Albu).
  • Working temp.: +5°C to +40°C.
  • Humidity: 30% to 90%.
  • Indications: Sound, yellow and green LEDs and pictograms.
  • Alarm inputs: Three inputs, with individual acknowledge mode, alarm function, alarm code, alarm receiver and protocol.
  • Microphones: Up to two external microphones with a built-in alarm button can be connected.
  • Power: Powered via 12-24 VDC port, but can also be powered via telephone line.
  • Loop amplifier: Connection to loop amplifier.
  • Programming: Built-in keyboard, standard DTMF telephone, flex programming app, via computer software and modem.
  • Alarm protocol: CPC, P100, P100 Extended.
  • Tone signals: DTMF.
  • Voice messages: Up to 2 different 16-second-long voice messages to be played on various occasions.
    Speech exchange: Duplex or simplex.
  • Test alarm: Once a day to once every third day (configurable).
  • Alarm receiver: Contact your distributor for information on existing alarm call centers that can receive the alarm protocol. All phones with tone selection (the buttons * and #) can receive the alarms. NOTE! FAR (Fältcom Alarm Receiver) G4 is specially designed to receive alarms from EC II Flex Duo elevator phones.
  • End-of-alarm: Via magnet alarm button, key switch, alarm button pulse sequence, or remotely. Sets up call to alarm receiver.