Emergency Telephone Telia ECII ® Flex COP DUO
  • Emergency Telephone Telia ECII ® Flex COP DUO
  • Emergency Telephone Faltcom ECII ®
  • Keypad Emergency Telephone Telia Faltcom ECII ® flex

Emergency Telephone Telia ECII ® Flex DUO COP

Reference: 202250

Product suitable for elevators

The Telia ECII ® Flex DUO COP emergency telephone is an alarm system designed for elevators intended for passenger transport.

When a trapped passenger presses the alarm button, Telia ECII ® Flex DUO COP automatically sends an alarm to a predefined telephone number, preferably a 24-hour service center, at which the elevator is identified.

Two-way voice communication is then established and the passenger can communicate with the service center operator, who can undertake the appropriate action.

The Telia ECII ® Flex DUO COP system was designed with a focus on safety, simplicity and high reliability of operation. This system was developed in close cooperation with professional end users and industrial designers.

The audio quality of Telia ECII ® Flex DUO COP is exceptional even in difficult environments with background noise.

The FältCom ECII® Flex DUO COP phone is mounted with security screws and the front plate is made of stainless steel and vandal-proof.

The Telia ECII ® Flex DUO COP emergency phone complies with the new EN81:28 2018
and has new features for an even better operating reliability.

THIS MODEL 

Name: Telia ECII ® Flex DUO COP - emergency telephone only + numeric keypad

Dimensions: 100x90x19 mm

Weight: 200 g

 

Safety Payments

 

Delivery

 

Return Policies

Product suitable for elevators

HOW DOES TELIA ECII FLEX DUO WORK?

The emergency phone is equipped with a built-in speaker, microphone, LED indicators, and input/outputs. It can be connected with a number of external devices, including intercom, loop amplifier, emergency power supply, Gateway etc. When adding a Gateway, a wireless telephone communication is created, enabling EC II Flex Duo to send alarms via the mobile network. When a passenger in an emergency presses the alarm button, the system automatically calls a pre-defined phone number. Bidirectional communication allows the person receiving the alarm to call the elevator and talk with the passenger. You can choose whether you wish for a pre-recorded voice message to be played inside the car, in order to calm passengers in an emergency.

Programming is easily done via a built-in keyboard, or remotely via standard telephone, Windows application Flex programmer, or the dedicated smartphone app. The elevator phone has a programmable input that can be used for e.g. an extra alarm button, technical alarm for the elevator controller, or filtration signals. It also has 2 programmable relay outputs that can be used for e.g. external pictograms, mechanical alarm button self test and/or elevator restart.

NEW FEATURES

  • Certified with EN81:28 2018 standard.
  • Updated audio software for all pre-recordedmessages.
  • 2 programmable relays.
  • Pictogram output.
  • Button self-test.Unified software.

ECII Flex Duo is CE-marked and meets the requirements of European Standards EN81:28 2018, EN81:70, EN81:71 and EN81:80.

PORTS

Alarm 1: Input for alarm button (Normally Open / Normally Closed)
Alarm 2: Extra alarm input for additional alarm buttons, technical alarm, filtration, alarm acknowledgement, etc. Loop amp: Output for loop amplifier.
Phone: Connection to PSTN or gateway.
AUX: For speech units.
DC: Input for external power supply.
2 Digital outputs: Isolated relays for external equipment e.g. pictogram, mechanical self test, elevator restart.

TECHNICAL SPECIFICATION

Enclosure: 1.5 mm stainless steel (ECII Flex Duo), 1.0 mm AluZinc (ECII Flex Duo Cop), 1.5 mm stainless steel (ECII Flex Duo Albu).
Working temp.: +5°C to +40°C.
Humidity: 30% to 90%.
Indications: Sound, yellow and green LEDs and pictograms.
Alarm inputs: Three inputs, with individual acknowledge mode, alarm function, alarm code, alarm receiver and protocol.
Microphones: Up to two external microphones with a built-in alarm button can be connected.
Power: Powered via 12-24 VDC port, but can also be powered via telephone line.
Loop amplifier: Connection to loop amplifier.
Programming: Built-in keyboard, standard DTMF telephone, flex programming app, via computer software and modem.
Alarm protocol: CPC, P100, P100 Extended.
Tone signals: DTMF.
Voice messages: Up to 2 different 16-second-long voice messages to be played on various occasions.
Speech exchange: Duplex or simplex.
Test alarm: Once a day to once every third day (configurable).
Alarm receiver: Contact your distributor for information on existing alarm call centers that can receive the alarm protocol. All phones with tone selection (the buttons * and #) can receive the alarms. NOTE! FAR (Fältcom Alarm Receiver) G4 is specially designed to receive alarms from EC II Flex Duo elevator phones.
End-of-alarm: Via magnet alarm button, key switch, alarm button pulse sequence, or remotely. Sets up call to alarm receiver.

 

Download

Telia emergency telephone

Full Datasheet Emergency telephone Telia (ex Faltcom) all ECII FLEX DUO versions

Download (222.39k)

Telia emergency telephone

Full Datasheet Emergency telephone Telia (ex Faltcom) all ECII FLEX DUO versions

Download (334.59k)

Manual User ECII Flex

Telia ECII Flex DUO Emergency Telephone User Manual

Download (1.37M)

Create your account now!